"Without the reliable and reproducible automated sample introduction offered by the TD100-xr, we would not be able to carry out long-term studies on this scale... The TD100-xr was a revelation."
Dr. Rebecca Cordell
Senior Research Scientist, University of Leicester, UK.
Market-leading advantages of TD100-xr
1. Eliminate helium dependency: Use hydrogen, nitrogen, or helium as a carrier gas for your automated sorbent tube analysis with our Multi-Gas TD100-xr.
2. Sample Security:
- Quantitative sample re-collection: Quantitative re-collection for repeat analysis offers simple method/data validation and overcomes the ‘one-shot’ limitation of historical systems.
- Tubes remain capped: Sample tubes stay capped at all times using patented DiffLok™ caps, avoiding contamination and analyte loss.
3. Cost saving: The electrically-cooled focusing trap eliminates the expense and hassle of liquid cryogen and prevents the risk of ice blockages, thus optimizing uptime. Choosing to operate with hydrogen carrier gas will also eliminate dependency on helium and its rising cost.
4. Time saving: Capacity for up to 100 tubes and the ability to use overlap mode allow you to maximize productivity (e.g., by running samples unattended all weekend).
5. Broadest available tube analyte and concentration range: Compatible with the analysis of VOCs and SVOCs from C3 to n-C44, including reactive and thermally labile species. Unbeatable split versatility (true-splitless to 125,000:1) enables both high-concentration and trace-level samples to be analysed.
6. Precision: Automated addition of an internal standard to the focusing trap or to a tube during analysis enhances the quality of your data.
7. High data quality: Automatic leak tests carried out before analysis of each sample ensure confidence in your data quality and full compliance with key regulated methods.
8. Reliability: Dry-purge or pre-purge automatically removes water and air from the sample before analysis, avoiding the risk of interference in the gas chromatograph and extending the lifetimes of your column and detector.
9. Simplified chain of custody: The on-board TubeTAG™ read/write functionality automatically updates tube and sample information during analysis.
10. Compliance with standard methods: Stringent leak testing, re-collection, and advanced water management ensure full compliance with key standard methods from bodies including US EPA, Chinese EPA, CEN, ISO, ASTM, HSE, JSA, and NIOSH.
11. Compatibility with GC and GC–MS from all major manufacturers: Minimizes the upfront investment required to investigate new TD markets for your lab.
12. Easy and intelligent operation: Built-in standard-method parameters, automated self-checking diagnostics, and usage/maintenance counters maximize instrument uptime.
For further support, please contact:
![]() | COE team Email: info@transmed.com.vn Hotline: 0949 934 595 |


